Sequential Site Work: Getting Equipment Delivery Timing Right
August 14, 2026A handheld X-ray fluorescence (XRF) analyser can report metals in soil within seconds. The harder question is whether that number can support a decision an auditor or regulator will rely on. In our experience, XRF works best as a field screening tool that guides where laboratory samples are taken, rather than a replacement for them.
The short answer: use portable XRF soil testing to screen for metals, map hotspots and guide excavation on site. Use NATA accredited laboratory analysis whenever data needs to withstand review by an auditor, regulator or court, such as formal reporting, waste classification, validation or an environmental audit.
What is portable XRF soil testing?
Portable XRF soil testing is a field screening method that uses a handheld analyser to measure the total concentration of metals and metalloids in soil. A portable XRF analyser directs X-rays at the soil and measures the energy each element gives off in response. It reports the total concentration of many metals and metalloids, including lead, arsenic, zinc, copper, chromium and nickel. Our Vanta handheld XRF analyser is available for hire and purchase.
The US EPA treats field portable XRF as a screening method to be used alongside confirmatory analysis (Method 6200), which broadly reflects how it is used in Australia.
Australian site assessment follows the National Environment Protection (Assessment of Site Contamination) Measure 1999, as amended in 2013 (the ASC NEPM). Schedule B1 sets the investigation levels that results are compared against, and Schedule B3 provides guidance on laboratory analysis.
Where does XRF add value on site?
XRF is most useful when many data points are needed quickly.
- Mapping hotspots. Dozens of readings can be taken across a grid in a morning, stepping outward from high results until values fall below the screening level.
- Guiding excavation. Readings on the excavation face can help the operator decide whether to dig deeper, which may keep clean soil out of the waste stream and reduce disposal costs.
- Targeting laboratory budget. Screening helps select a spread of high, medium and low samples for the laboratory, building a site-specific relationship between field and laboratory data.
What are the limitations of portable XRF?
- Elements only. XRF cannot detect hydrocarbons, PAHs, pesticides or PFAS. It reports total chromium and cannot separate hexavalent from trivalent chromium, and very light elements are below its range.
- Sample condition. Moisture tends to lower readings, and coarse or mixed material increases variability. Drying, sieving and bagging samples generally improves consistency, so in situ readings suit quick screening while prepared ex situ readings are more reliable.
- Spectral interference. Lead and arsenic overlap on the spectrum, so high lead can affect arsenic results. A confirmatory laboratory sample is worthwhile where both are present.
- Total versus acid extractable. Schedule B3 laboratory methods for metals use acid digestion, while XRF measures the total element. XRF may therefore read higher for some elements, which is worth keeping in mind when comparing field and laboratory data.
For more on contaminants XRF cannot detect, read our post on how Australia is tackling PFAS in water supplies.
Portable XRF vs laboratory analysis: how do they compare?
Portable XRF offers speed and coverage on site, while NATA accredited laboratory analysis provides the data auditors and regulators generally expect. The table below summarises the key differences.
| Factor | Portable XRF | NATA accredited laboratory |
|---|---|---|
| Speed | Seconds, on site | Laboratory turnaround |
| What it reports | Total concentration of metals and metalloids | Metals by acid digestion, plus organics and specific chemical forms |
| Organics (hydrocarbons, PAHs, pesticides, PFAS) | Not detected | Analysed |
| Chromium | Total chromium only | Hexavalent and trivalent can be separated |
| Sample preparation | In situ, or dried, sieved and bagged ex situ | Full laboratory preparation |
| Best used for | Mapping hotspots, guiding excavation, targeting laboratory budget | Formal reporting, waste classification, validation, environmental audits |
When is laboratory analysis needed?
Where data needs to withstand review by an auditor, regulator or court, NATA accredited laboratory analysis is generally expected. This typically includes:
- comparing results against NEPM investigation levels in a formal report
- classifying soil for off-site disposal (in Victoria, under EPA Publication 1828.2 and IWRG702 Soil sampling for waste soils)
- validating a remediated area before sign-off
- preparing data for an environmental audit
- testing for organics or chemical forms such as hexavalent chromium.
Results near a criterion warrant particular care. The NEPM health investigation level for lead under HIL A (residential with garden or accessible soil, childcare centres, preschools and primary schools) is 300 mg/kg. A field reading of 280 mg/kg is not a reliable indication that soil sits below this level, and would justify a confirmatory laboratory sample.
It is also worth remembering that HILs are investigation levels, not clean-up levels. An exceedance indicates further investigation is needed rather than an unacceptable risk. For lead in residential settings, AS 4874-2000 provides guidance on investigating soil and deposited dust, with particular emphasis on areas used by young children.
How should XRF and laboratory analysis be used together?
Combining XRF and laboratory analysis usually gives a better site picture than either alone, often at a lower total cost. A practical workflow may look like this:
- Set screening levels before mobilising, based on your data quality objectives.
- Check the analyser against certified reference materials at the start and end of each day.
- Screen across a grid to map concentrations and boundaries.
- Prepare a subset of samples and test them ex situ.
- Send a spread of high, medium and low samples to a NATA accredited laboratory.
- Compare field and laboratory results and adjust the approach if needed.
A strong field to laboratory correlation may allow greater reliance on XRF for the rest of the project. A weak one is an early warning that the soil matrix is affecting results.
Pair your analyser with the right field gear from our soil sampling range, or browse the full elemental analysis range.
Should you hire or buy a handheld XRF analyser?
Whether to hire or buy depends on how often you will use the analyser. Hire suits one-off investigations, busy periods or trialling the technology, without the upfront cost or servicing load. Consultancies carrying out portable XRF soil testing most weeks may find that owning a unit pays off over time.
Our rental range covers short and long hires, with same-day delivery across metro Melbourne and overnight shipping to other capitals. If ownership makes more sense, our equipment sales team can talk through purchase options.
Do you need a licence to use a handheld XRF analyser?
Handheld XRF analysers emit ionising radiation and are regulated by each state and territory, so requirements vary. In Victoria, the Department of Health administers the Radiation Act 2005. The business that possesses the analyser needs a radiation management licence and must meet the Department’s mandatory requirements for non-enclosed X-ray analysis units. Individual operators of XRF analysers are currently exempt from holding a use licence. In other jurisdictions, we suggest checking with the relevant radiation regulator before the first job. Training remains important for both safety and data quality.
Keep an eye on our training page for upcoming sessions.
Frequently asked questions
How accurate is portable XRF for soil testing?
Accuracy depends on sample condition, the element measured and its concentration. Moisture tends to lower readings, and coarse or mixed material increases variability, so prepared ex situ readings are more reliable than in situ readings. XRF measures the total element, so it may read higher than acid-digestion laboratory results for some elements.
Can portable XRF detect asbestos?
No. XRF measures elements, not mineral fibres, so it cannot identify asbestos. Asbestos in soil requires identification by a NATA accredited laboratory.
Can XRF detect PFAS or hydrocarbons?
No. XRF detects elements only, so hydrocarbons, PAHs, pesticides and PFAS require laboratory analysis.
Do XRF operators need a licence in Victoria?
Individual operators of XRF analysers are currently exempt from holding a use licence in Victoria. The business that possesses the analyser needs a radiation management licence and must meet the Department of Health’s mandatory requirements for non-enclosed X-ray analysis units.
Can XRF results be used in a formal site contamination report?
XRF results are best treated as screening data. Where results are compared against NEPM investigation levels in a formal report, NATA accredited laboratory analysis is generally expected.
Field speed, laboratory certainty
Portable XRF is not a substitute for laboratory analysis, and it was not designed to be. Its value lies in speed, coverage and better decisions on the day. Paired with a well-prepared field program and confirmatory NATA accredited analysis, portable XRF soil testing can help produce data that is both efficient and defensible.
Planning a metals investigation? Book a handheld XRF analyser or contact our team to discuss the right setup for your site.
Sources
- ASC NEPM 1999 (as amended 2013), Schedule B3
- NEPC, Health investigation levels factsheet
- AS 4874-2000, Standards Australia
- US EPA Method 6200
- Victorian Department of Health, Do you need a use licence
- Victorian Department of Health, X-ray analysis units
- EPA Victoria Publication 1828.2
- EPA Victoria IWRG702