Landfill Monitoring

  • GasClam – Continuous Ground Gas Monitor

    GasClam® is a ground gas monitor to give constant, unsupervised data collection. This system is ideal for landfill gas monitoring applications. The GasClam® monitors and logs continuous long-term data. Gas management and risk prediction can now be made on accurate and reliable data.

    Description:

    GasClam® is a ground gas monitor for constant, unsupervised data collection. This system is ideal for landfill gas monitoring applications. The GasClam® monitors and logs continuous long-term data. Gas management and risk prediction can now be made on accurate and reliable data.

    The landfill gas monitor can measure methane (CH4), carbon dioxide (CO2), oxygen (O2), carbon monoxide (CO), hydrogen sulphide (H2S) and voletile organic compounds (VOC) concentrations as well as atmospheric pressure, borehole pressure, temperature and water level. A telemetry module for remote, real time data communication is also possible.

    GasClams sampling frequency can be set at a variable from two minutes, to once daily. Data can then be downloaded to a PC.

    Quick Specs:

    • GasClam® ground gas monitor is Intrinsically Safe.
    • Monitors a range of gasses and other environmental parameters.
    • Manufactured from stainless steel.
    • Environmentally sealed and ingress protection rated IP-68.
    • Battery operated and can be run for up to 1 month on hourly sampling.GasClam User Manual:( 12-01-2017)Download Pdf
  • Geotech GA5000 Portable Landfill Gas Analyser

    Description:

    The GA5000 is a portable landfill and contaminated land gas analyser with sensors for measurement of Methane (CH4), Carbon Dioxide (CO2), Oxygen (O2), Hydrogen Sulphide (H2S) and Carbon Monoxide (CO). Applications include landfill gas monitoring, waste to energy, contaminated land and site investigation.

    Quick Specs:

    • Measures % concentrations of CH4, CO2 and O2.
    • Measures ppm concentrations of H2S and CO.
    • Measures pressure and flow of gas
    • Simultaneous display of all gases
    GA5000-Operating Manual:( 24-11-2016)
    Download Pdf
    GA5000-Software Manual:( 12-01-2017)
    Download Pdf
  • Huberg LASER ONE

    Huberg LASER One

    A hand-held laser based natural gas detection instrument.  The LASER One is a portable natural gas leak analyser that uses laser spectroscopy.  This highly sensitive detector offers all the advantages of optical detection in a compact and portable device.  The Huberg LASER One gives you precise and reliable findings when detecting methane leaks.

    The LASER One instrument has selective measurement of methane due to the laser technology used, and delivers reliable and accurate measurements of methane concentrations, irrespective of whether the sample contains other gases or hydrocarbons.  Due to its lightweight design and modest size, LASER One can be easily transported and is ideal for measuring methane concentrations in the field (landfills, site investigations or gas networks).


    Quick Specs

    • Laser technology specific to methane
    • Intrinsically safe, ATEX Certified – Zone 1
    • Wide measurement range (0 ppm to 100% volume)
    • Integral GPS and Bluetooth
    • Lightweight
    • Hot swap battery
    • Multiple reporting functions
    • Easy to use
    • All day operation
  • Inspectra Laser

    The Inspectra Laser is a natural gas leak portable analyzer with laser spectroscopy. This highly sensitive detector offers all the advantages of optical detection in a highly compact and portable device, giving you precise and reliable findings when detecting methane leaks.

    Description:

    The Inspectra Laser is a methane detector offering 1 ppm detection sensitivity. The instrument is ATEX certified and makes it possible to detect methane leaks and determine their location with precision.

    Quick Specs:

    • Total selectivity to methane.
    • Measurement range, from 1ppm to 100% gas volume.
    • ATEX certified.
    • User-friendly.
    • Light weight (2.7 kg with batteries).
    • Compact design for maximum working comfort.
    Gazomet Inspectra Laser-Manual:( 12-01-2017) Download Pdf
  • Miasma Meter

    Miasma Meter

    Coming soon!  The Miasma Meter is being developed and trialled in Victoria.  It will deliver simpler and smarter technology for long term monitoring of the concentration and flow rate of methane and other ground gases in monitoring wells.  Join our newsletter if you want to be kept up to date on the latest from Miasma Meter.

  • MiniRae 3000

    Measures volatile organic compound (VOC) concentrations in real time.

    Description:

    MiniRAE 3000 is a handheld volatile organic compound (VOC) monitor.

    Its photoionization detector’s (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene to leak detection and HazMat.

    Quick Specs:

    • Detection range of 0 to 15,000 ppm.
    • Correction factors for over 200 VOCs built in.
    • Supplied with standard 10.6 eV lamp (other lamps available, 9.8eV and 11.7eV).
    • Field calibratable
    MiniRae 3000 Pocket Reference:( 10-01-2017) Download Pdf
  • RKI GX-6000 Gas Detector

    The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.

    Quick Specs

    • 5 Operating modes
    • Smallest 6 gas sample draw
    • 2 Interchangeable smart sensor slots
    • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
    • PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
    • Benzene specific version
    • PPM Leak Check mode
    • LEL sensor protection mode
    • Man-down alarm
    • Panic alarm
    • Auto display rotation
    • Peak-bar display
    • LED Light source
    • Internal sample pump
    • Light weight, small, rugged IP-67
    • Interchangeable battery packs
    • Operates up to 14 hours
    • Field replaceable sensors, batteries, filters and pump
    • Intrinsically safe ATEX / IECEx / cCSAus
  • Rotating Vane Anemometer

    Accurately measures air velocity and temperature, calculates flow rate, performs averaging, and can determine minimum and maximum readings. Using sweep mode you can quickly provide one averaged reading of velocity or volume over a large measurement area. The large vane head automatically averages velocity and volume readings. The VelociCalc 5725 includes variable time constant, sampling and statistics functions and data logging capability.


    Quick Specs
    Reversible 4-inch (100 mm) head to read supply and exhaust flows
    Sampling function records multiple point measurements
    Automatic averaging of air velocity
    Simultaneously displays velocity and temperature
    Sweep mode for one overall measurement